Engineered with patented surge elimination and power conditioning technologies, SurgeX Space Savers protects ProAV equipment from AC surges and electrical transients that can disrupt sound quality and digital performance.

Our Advanced Series Mode technology is completely non-sacrificial and eliminates surge energy without producing harmful side effects such as ground contamination or common-mode disturbances.

Comprehensive protection technology also includes common mode and normal mode Impedance Tolerant EMI/RFI filtering, SurgeX ICE -Inrush Current Elimination, and COUVS -Catastrophic Over/Under Voltage Shutdown.
Part Number: SX-XC-24
Operational Voltage Range: 90 to 150 Volts AC
Current rating: 15/20 Amps
Power Rating: 1,800/2,400 Watts
Maximum Load Inrush Energy: 1000 Joules total during power-up
Under-Voltage Shutdown: 90 V (resume at 100V)
Over-Voltage Shutdown: 145V (resume at 135V)
Surge Let-through Voltage: Zero let-through Voltage for a 6000 Volt surge
Meets Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
EMI/RFI Filter, Normal Mode: 40 dB @ 100 KHz, 50dB @ 300 KHz, 50 dB @ 3 MHz, 50 dB @ 30 MHz (50 Ohm load)
EMI/RFI Filter, Common Mode: 18dB @ 300 KHz, 30 dB @ 1 MHz, 50 dB @ 5 MHz, 50 dB @ 20 MHz (50 Ohm load)
Maximum Applied Surge Voltage: 6,000 Volts
Maximum Applied Surge Current: Unlimited (due to current limiting)
Maximum Applied Surge Energy: Unlimited (due to current limiting)
Endurance: (C62.41-1991 category B3 pulses), 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
Remote Control Voltage: 5 to 30 Volts DC
Remote Control Current Draw: 4 mA maximum
Contact Closure Max. Resistance: 100 Ohms
Auxiliary Relay Contact Rating: 30 Volts DC at 1 Amp
12 Volt Output Max. Current: 20 mA
Humidity Range:5% to 95% R.H. Non-condensing
Agency Listings: ETL and cETL (UL 1449, Third Edition, Type 3 Surge Protective Device; UL 1283; CSA C22.2 No.8-M1986, R2004). Listed as base models SX-1115-RT, SX-1120-RT.
Engineered with patented surge elimination and power conditioning technologies, SurgeX Space Savers protects ProAV equipment from AC surges and electrical transients that can disrupt sound quality and digital performance.

Our Advanced Series Mode technology is completely non-sacrificial and eliminates surge energy without producing harmful side effects such as ground contamination or common-mode disturbances.

Comprehensive protection technology also includes common mode and normal mode Impedance Tolerant EMI/RFI filtering, SurgeX ICE -Inrush Current Elimination, and COUVS -Catastrophic Over/Under Voltage Shutdown.
Part Number: SX-XC-18
Operational Voltage Range: 90 to 150 Volts AC
Current rating: 15/20 Amps
Power Rating: 1,800/2,400 Watts
Maximum Load Inrush Energy: 1000 Joules total during power-up
Under-Voltage Shutdown: 90 V (resume at 100V)
Over-Voltage Shutdown: 145V (resume at 135V)
Surge Let-through Voltage: Zero let-through Voltage for a 6000 Volt surge
Meets Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
EMI/RFI Filter, Normal Mode: 40 dB @ 100 KHz, 50dB @ 300 KHz, 50 dB @ 3 MHz, 50 dB @ 30 MHz (50 Ohm load)
EMI/RFI Filter, Common Mode: 18dB @ 300 KHz, 30 dB @ 1 MHz, 50 dB @ 5 MHz, 50 dB @ 20 MHz (50 Ohm load)
Maximum Applied Surge Voltage: 6,000 Volts
Maximum Applied Surge Current: Unlimited (due to current limiting)
Maximum Applied Surge Energy: Unlimited (due to current limiting)
Endurance: (C62.41-1991 category B3 pulses), 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
Remote Control Voltage: 5 to 30 Volts DC
Remote Control Current Draw: 4 mA maximum
Contact Closure Max. Resistance: 100 Ohms
Auxiliary Relay Contact Rating: 30 Volts DC at 1 Amp
12 Volt Output Max. Current: 20 mA
Humidity Range:5% to 95% R.H. Non-condensing
Agency Listings: ETL and cETL (UL 1449, Third Edition, Type 3 Surge Protective Device; UL 1283; CSA C22.2 No.8-M1986, R2004). Listed as base models SX-1115-RT, SX-1120-RT.